<< Back
CALIBRATION OF ELECTRONIC WEIGHING EQUIPMENT

Standard calibration of weighing equipment (covered by accreditation) is estimating the terror of the weighing equipment in maximally 5 measuring points and the terror of eccentricity. Additionally, it is possible to perform the dispersion of the readings for 50 % load and 100 % load and evaluation for compatibility with regulations included in Decree of Ministry of Economy, Work and Social Policy" from 3rd of October 200, on requirements which go for non-automatic weighing equipment (Dz. U. Nr 183, poz.1791), Norm PN EN 45501:1999 "Metrological Requirements for Non-automatic Weighing Equipment " and Directive of European Council 90/384/EEC " Metrological Requirements for Non-automatic Weighing Equipment ".

Full range of calibration of weighing equipment is presented on below table:

 
Measuring tool: Measuring range Best measuring possibility
1. Non-automatic electronic weighing equipment:    
    a) analytical balances from 1 mg to 400 g 0,6 d
    b) laboratory, technical and industrial scales and balances
from 1 mg to 3000 kg
0,6 d
from 1kg to 60 000 kg 0,1 d gdy d 0,5 e
    c) weighbridges*   0,1 d
2. Electronic, dynamic checkweighers* from 1 g to 50 kg static - 0,6 d
dynamic - 1 d
*) no accreditation. d - reading unit  
e - verifying unit
 
See:
- example of results from calibration certificate
©2005 RADWAG Wagi Elektroniczne. All rights reserved.
All proprietor's rights do the materials placed in the server are in possession of RADWAG Wagi Elektroniczne and are
not to be copied, processed and utilized in commercial purpose unless agreed with RADWAG Wagi Elektroniczne.