RADWAG BloggerRADWAG FacebookRADWAG RSS

Balances compteuses WLY
WL2Y D2   WLY C1/R
WLY C2/R
  WLY C1/K
WLY C2/K
 


Application:
WLY counting scales are designed to count pieces with equal unit mass. Scales are connectable to label printers for matching weighed goods with labels. The WLY counting scales are Radwag response to increasing market demand for simple operation and maximal automation of weighing process. Scales can also cooperate with barcode scanners, receipt printers, label printers, RFID scanners and PC peripherals  like keyboard, mouse, USB flash memory.

Counting system software possibilities:
- setting single detail mass on main weighing platform with high resolution,
- printing labels, c and cc labels,
- choosing product from product database using bar code scanners,
- cooperation with additional weighing platform.

Design and functionality
All types of WLY counting scales feature stainless steel weighing platform, an indicator with TFT 5,7’’ touch screen and membrane keyboard front panel. WLY counting scale enable plugging of an additional weighing platform and provide below functions:
- programming of display and functional keys,
- programming of infrared proximity sensors,
- designing printouts,
- designing text data that are displayed in the indicator display.


 
  Scale requires two stages of verification process (external calibration is not accessible). Due to the influence of gravitational acceleration forcem the scale has to be calibrated on site. calibration cost depends on the location of instrument's installation.
 
Data exchange through USB storage devices
- update scale software
- export weighing data
 

5,7'' touch screen
Infrared proximity sensors
Programmable 40 functions (PRINT, TARE and others).

  Communication interfaces
- Ethernet
- 2×RS 232
- 2×USB
- 4 in/4 out

In standard scale has built in function of "Counting pieces" and "Checkweighing".

 
   
 
Fonctions:
Comptage
Totalisation
Etiquettage
Pourcentage
Staistiques
Capteurs infrarouges
     *
* Les details dans le
   tableau de parametres
   techniques
2 ans garantie
 
Télécharges (PDF):
Product folder
User manual
Declaration of conformity
 
Parametres techniques: WLY/2 1/D2 WLY/2 2/D2 WLY/2 6/D2 WLY/2 10/D2 WLY/2 20/D2
- - - -
Max capacité 1 kg 2 kg 6 kg 10 kg 20 kg
Min capacité - - 5 g - -
Précision 0,01 g 0,01 g 0,1 g 0,1 g 0,1 g
Echelon homologue - - 1 g - -
Plage de tarage -1 kg -2 kg -6 kg -10 kg -20 kg
Répétabilité 0,03 g 0,03 g 0,3 g 0,3 g 0,3 g
Linéarité ±0,03 g ±0,03 g ±0,3 g ±0,3 g ±0,3 g
Classe OIML - II -
Plateau 195×195 mm
Temps de stabilisation 3 s
Temperature de travail +15 ° - +30 °C
Temperature de stockage -25 ° - +70 °C
Niveau de protecion IP 54
Alimentation 110÷230VAC 50/60Hz / 10,5÷15VDC
Calibration externe
Afficheur 5,7'' touch screen
Interface 2×USB, 2×RS 232, Ethernet, 4Inputs/4Outputs
Masse net/brut 2,7/3,6 kg
Dimensions de colis 490×300×150 mm
 
Parametres techniques: WLY/2 0,6/1,2/D2 WLY/2 1,2/3/D2 WLY/2 3/6/D2 WLY/2 6/12/D2
- - - -
Max capacité 0,6/1,2 kg 1,2/3 kg 3/6 kg 6/12 kg
Min capacité - - - -
Précision 0,01/0,02 g 0,02/0,05 g 0,05/0,1 g 0,1/0,2 g
Echelon homologue - - - -
Plage de tarage -1,2 kg -3 kg -6 kg -12 kg
Répétabilité 0,01/0,02 g 0,02/0,05 g 0,05/0,1 g 0,1/0,2 g
Linéarité ±0,01/0,02 g ±0,02/0,05 g ±0,05/0,1 g ±0,1/0,2 g
Classe OIML -
Plateau 195×195 mm
Temps de stabilisation 3 s
Temperature de travail +15 ° - +30 °C
Temperature de stockage -25 ° - +70 °C
Niveau de protecion IP 54
Alimentation 110÷230VAC 50/60Hz / 10,5÷15VDC
Calibration externe
Afficheur 5,7'' touch screen
Interface 2×USB, 2×RS 232, Ethernet, 4Inputs/4Outputs
Masse net/brut 2,7/3,6 kg
Dimensions de colis 490×300×150 mm
 
Parametres techniques: WLY 6/C1/R WLY 12/C1/R WLY 30/C1/R WLY 60/C2/R WLY 120/C2/R
WLY 6/C1/K WLY 12/C1/K WLY 30/C1/K WLY 60/C2/K WLY 120/C2/K
- - -
Max capacité 6 kg 12 kg 30 kg 60 kg 120 kg
Min capacité 5 g - - 50 g -
Précision 0,1 g 0,2 g 0,5 g 1 g 2 g
Echelon homologue 1 g - - 10 g -
Plage de tarage -6 kg -12 kg -30 kg -60 kg -120 kg
Répétabilité 0,3 g 0,6 g 1,5 g 1 g 2 g
Linéarité ±0,3 g ±0,6 g ±1,5 g ±1 g ±2 g
Classe OIML II - II -
Plateau 360×290 mm 400×500 mm
Temps de stabilisation 3 s
Temperature de travail +15 ° - +30 °C
Temperature de stockage -25 ° - +70 °C
Niveau de protecion IP 54
Alimentation 110÷230VAC 50÷60Hz / 10,5÷15VDC
Calibration externe
Afficheur 5,7'' touch screen
Interface 2×USB, 2×RS 232, Ethernet, 4Inputs/4Outputs
Masse net/brut 6,5/7,8 kg
Dimensions de colis 550×420×220 mm
 
Parametres techniques: WLY 6/12/C1/R WLY 12/30/C1/R WLY 60/120/C2/R
WLY 6/12/C1/K WLY 12/30/C1/K WLY 60/120/C2/K
- - -
Max capacité 6/12 kg 12/30 kg 60/120 kg
Min capacité - - -
Précision 0,1/0,2 g 0,2/0,5 g 1/2 g
Echelon homologue - - -
Plage de tarage -12 kg -30 kg -120 kg
Répétabilité 0,1/0,2 g 0,2/0,5 g 1/2 g
Linéarité ±0,1/0,2 g ±0,2/0,5 g ±1/2 g
Classe OIML -
Plateau 360×290 mm
Temps de stabilisation 3 s
Temperature de travail +15 ° - +30 °C
Temperature de stockage -25 ° - +70 °C
Niveau de protecion IP 54
Alimentation 110÷230VAC 50÷60Hz / 10,5÷15VDC
Calibration externe
Afficheur 5,7'' touch screen
Interface 2×USB, 2×RS 232, Ethernet, 4Inputs/4Outputs
Masse net/brut 6,5/7,8 kg
Dimensions de colis 550×420×220 mm
Equipement supplementaire:
Table antivibratoire pour balances de laboratoireBoucle de courant AP2-1 (version en plastique)
Imprimante thermique KafkaPoignée pour indicateur PUE 7
Imprimante a eguille EpsonLecteur de cartes: CK-01
Imprimante d'etiquette CitizenLecteur de code à barre
Logiciel "PW-WIN"Module DP2
Afficheur supplementaire LCD "WD-4/4"Cable RS 232 (balance - imprimante Kafka) "P0136"
Clavier PCCable RS 232 (balance - ordinateur) "P0108"
Poids de calibrationCable RS 232 (balance - imprimante Epson, Citizen) "P0151"
Etalon de masseCable d"alimentastion - allume cigare: "K0047"
Pour en savoir plus appuyez sur la position choisie.
© 2005 RADWAG Wagi Elektroniczne. Tous droits réservés.
Tous les droits aux materiels emis sur le site apartient à RADWAG Wagi Elektroniczne et ils ne peuvent pas être copiés,
transformés, ni commercialisés sans l'accord RADWAG Wagi Elektroniczne.